High Security Door
It may look like a standard rolling door from the outside, but the robust steel curtain features interlocking slats that compress when in the closed position, creating a smooth surface that reduces potential pry points. As the attack continues, the interlocking slats engage further to prevent separation and make the door even more durable. It also features a reinforced bottom bar and discreet locking system that eliminates the ability to lift the door.
The EntryDefender Door is so impressive, it won a Platinum Award for Best Critical Infastructure Protection Solution at the 2019 Astors Awards given by the American Security Today Magazine.
Sizes
The maximum size available will vary slightly based on the wall construction.
If the wall construction is steel, the maximum size is 13’ 11 1/4" wide by 16’ high.
If the wall construction is concrete, the maximum size is 13' 8 3/4" wide by 16' high.
For openings that fall outside of the standard construction, please contact us.
Usage
The EntryDefender Door is designed to operate to 20,000 cycles (lifetime) as standard, but can also be customized to handle additional cycles if desired.
Standard Materials & Finishes
The standard materials and finishes for EntryDefender are:
- Curtain – 12 gauge 4” flat steel slat with SpectraShield® powder coat in gray.
- Guides – Steel with powder coating to match the curtain.
- Bottom Bar – 12 gauge 4” face steel bottom bar with powder coat to match the curtain.
Available Operators
The EntryDefender Door features the SG motor operator as standard. It is UL-325 listed with a chain and sprocket drive. It also includes an interlock to prevent operation while locks are engaged.
Listing
The EntryDefender Door meets the U.S. Department of State Standard for forced entry SD-STD-01.01, Revision G (Amended) for a 5, 15 and 60 minute attack.
The EntryDefender Door is ASTM F3038 Compliant.
The government standard for forced entry (CODE) was designed for attacks that escalate – not planned attacks. That’s why the testing required for this code requires six men between the ages of 18 and 24 that weigh more than 160 but less than 250 pounds to try and pass a rigid rectangular shape measuring 12” x 12” x 8” or a rigid 12” x 12” cylinder through the door using hand tools such as battering rams, axes, crowbars, and the like.
Resistance Rating
| Model # | Resistance Rating |
|---|---|
| PED0101-05 | 5 minutes |
| PED0101-15 | 15 minutes |
| PED0101-60 | 60 minutes |
Static Wind Load
The EntryDefender door is designed for a static wind load of up to 125 psf.