Skip to main content

Building Codes, Listings and Letters

It’s difficult to stay up to date with ever-evolving building codes, listings, project requirements and letters. Here, you can find out what building codes and listings our products meet and gather the necessary documentation for your project. Browse through all of our listings, or click on the organization you are interested in below.

Cornell and Cookson

Underwriter's Laboratory (UL) | Factory Mutual (FM) | California State Fire Marshal  | Specified Wind Load | 
ICC 500 Test Results | Seismic Performance Calculations | Air Infiltration | Sound Transmission Class (STC) | ISO 9001  |   OSHPD Preapproval of Manufacturer's Certification (OPM) | Forced Entry / Ballistic Resistance (SD-STD-01.01)

Clopay

DASMA | MSDS | Windcode

UL Listings

NameUL CategoryCertified for CanadaRated For
Fire and Smoke Rated Rolling Doors without Egress
Rolling Fire DoorsRolling-Steel Type Fire Doors

4 hour, 3 hour, 1-1/2 hour, 1 hour or 3/4 hour

UL Control Number: GSVV.R1422

Canadian Control Number: GSVV7.R1422

SmokeShield Rolling Fire DoorsLeakage Rated Door Assemblies 

Leakage Rated

UL Control Number: OPBW.R1422

 

Firemiser Insulated Rolling Fire DoorsRolling-Steel Type Fire Doors

4 hour, 3 hour, 1-1/2 hour, 1 hour or 3/4 hour

UL Control Number: GSVV.R1422

Canadian Control Number: GSVV7.R1422

SmokeShield ElevatorLeakage Rated Door Assemblies 

Leakage Rated

UL Control Number: OPBW.R25122

ICC-ES Evaluation Report: ESR-4174

SmokeShield Insulated Rolling Fire DoorsLeakage Rated Door Assemblies 

Leakage Rated

UL Control Number: OPBW.R1422

Fire and Smoke Rated Counter Doors without Egress
Counter Fire Doors (Up to 12'W x 10'H)Service Counter Type Fire Doors

1-1/2 hour, 1 hour or 3/4 hour

UL Control Number: GSWT.R15854

Canadian Control Number: GSWT7.R15854

Counter Fire Doors (From 12'W x 10'H to 16'W x 7'6"H oversize)Rolling-Steel Type Fire Doors

3 hour, 1-1/2 hour, 1 hour or 3/4 hour

UL Control Number: GSVV.R1422

Canadian Control Number: GSVV7.R1422

SmokeShield Counter Fire DoorsLeakage Rated Door Assemblies 

Leakage Rated

UL Control Number: OPBW.R1422

Counter Fire Doors with Integral FrameService Counter Type Fire Doors

1-1/2 hour, 1 hour or 3/4 hour

UL Control Number: GSWT.R15854

Canadian Control Number: GSWT7.R15854

Labeled CountertopsMiscellaneous Fire Door Accessories

1-1/2 hour

UL Control Number: GVUX.R15865

Canadian Control Number: GVUX7.R15865

Operators for Rolling Fire Doors
Retrofit Fire Door OperatorsRetrofit Rolling Steel Fire Door Operators

Operator Classification

UL Control Number: GUNL.R22357

Canadian Control Number: GUNL7.R22357


Back to Top

Factory Mutual (FM)

The following documents are excerpts from the FM Approval Guide that list Cornell product. A complete FM Approval Guide is available through the Factory Mutual Website.


Back to Top

California State Fire Marshal (CASFM)


Back to Top

Wind Load Listings

Cornell Coiling, Thermiser Insulated Coiling and Fire doors can be configured to withstand the full range of specific wind load requirements including missile impact ratings. Specified wind load designs have been performance validated through third party testing to one or more of the following performance criteria:

  • ANSI/DASMA-108
  • ASTM E 330
  • Miami-Dade County test protocols TAS 201, TAS 202 and TAS 203
  • Florida Building Code (FBC)
  • Texas Department of Insurance (TDI)
  • Signed and Sealed Calculations

Miami-Dade County NOAs

Notice of ApprovalFlorida Building Code EditionProductSizeImpact SpeedLarge & Small
Missile Impact
PSF +/-High Velocity Hurricane ZoneExpiration Date
20-0925.08 2020Non-Insulated Service Door (ESD10) Up to 14'-5" Wide50 FPSX65XJuly 9, 2025
20-0925.07 2020Non-Insulated Service Door (ESD10) Up to 14'-5" Wide80 FPSX65XJuly 9, 2025
20-0925.11 2020Non-Insulated Service Door (ESD10) Up to 25'-5" Wide80 FPSX65XJuly 9, 2025
20-0925.06 2020Insulated Service Door (ESD20 & ESD30) Up to 12'-5" Wide50 FPSX65XJuly 9, 2025
20-0925.12 2020Insulated Service Door (ESD20 & ESD30) Up to 12'-5" Wide80 FPSX65XJuly 9, 2025
20-0925.09 2020Insulated Service Door (ESD20 & ESD30) Up to 14'-5" Wide80 FPSX120XJuly 9, 2025
20-0925.10 2020Insulated Service Door (ESD20 & ESD30) Up to 25'-5" Wide80 FPSX65XJuly 9, 2025
20-0925.13 2020Perforated Standard Service Door (ESD10) Up to 27'-5" Wide50 FPSX60XNovember 12, 2025
20-0925.14 2020StormDefender (PSD361) Up to 14' Wide80 FPSX200XJanuary 9, 2025

Florida Building Code (FBC)

FBC EditionFL #Product
2020FL-14636-R7 Roll-Up Exterior Door Assemblies (ESD10, ESD20 & ESD30)
2020FL17419-R5 Roll-Up Exterior Door Assemblies (ESD10, ESD20 & ESD30)
2020FL19074-R3 Roll-Up Exterior Door Assemblies (ESC10)
2020FL28885-R2 Roll-Up Exterior Door Assemblies (PSD361)
2020FL 32650.02 Roll-Up Exterior Door Assemblies (EPD300 & EDP1024)
2020FL 32845.02 Roll-Up Exterior Door Assemblies (EPD300 & EDP1024)
2020FL 32650.01 Roll-Up Exterior Door Assemblies (EPI300 & EDI1024)
2020FL 32845.01 Roll-Up Exterior Door Assemblies (EPI300 & EDI1024)

Texas Department of Insurance (TDI)

IBCProduct(s)GDRMissile Level D (50 FPS)Missile Level E (80 FPS)Non-Impact
2018CP0020 Non-Insulated Steel Roll-up Doors (ESD10)GDR-30 (PDF) ES-16-66-CIW ES-16-67-CIW ES-16-68-CIW
2018CP0001/CP0651 Insulated Steel Roll-up Doors (ESD20 & ESD30)GDR-31 (PDF) ES-16-69-CIW ES-16-70-CIW ES-16-71-CIW
2018 CP0005 Steel Roll-up Counter Doors, Impact Resistant (ESC10)GDR-122 (PDF)

ES-16-76-CIW

  
2018 StormDefender Non-Insulated Steel Roll-Up DoorsGDR-133 (PDF) ES-16-81-CIW   
2018 CP0020 High Performance Non-Insulated Steel Roll-up Doors, Impact Resistant and Non-Impact ResistantGDR-143 (PDF)    
2018 CP0001/CP0651 High Performance Insulated Steel Roll-up Doors, Impact Resistant and Non-Impact ResistantGDR-144 (PDF)    

Back to Top

ICC 500 Test Results

ICC 500-2014

The StormDefender Door is tested and certified to strongent ICC 500-2014 and FEMA P-361, third edition code standards.

View test results.

ICC-ES

SmokeShield® Elevator: ICC-ES Evaluation Report ESR-4175

ICC-ES Rules of Procedure for Evaluation Reports

ICC-ES True Copy Letter


Back to Top

 

Seismic Performance Calculations per ASCE 7-10

Cornell can provide seismic calculations for all Service (ESD10), Thermiser® (ESD20 & ESD30), Fire (ERD10) and Firemiser® (ERD20) doors that are mounted Face of Wall or Between Jambs to steel or masonry. Seismic performance validation is per ASCE 7-10.


Back to Top

Air Infiltration

Thermiser Max® Insulated Doors meet ASHRAE® 90.12, 2015 IECC® and California’s Title 24 air infiltration requirements with an independently tested value of less than 0.3 CFM/FT2.


Back to Top

 

GYR: ISO 9001 : 2015

Through an audit, documented in a report, it was verified that the management system fulfills the requirements of the following standard: ISO 9001 : 2015 .

MT: ISO 9001 : 2015

Through an audit, documented in a report, it was verified that the management system fulfills the requirements of the following standard: ISO 9001 : 2015.


Back to Top

 

Acoustical Testing Reports - Sound Transmission Class (STC) Rating

Thermiser (ESD20) Insulated Rolling Door has a Sound Transmission Class rating of up to 30 for the curtain and up to 18 for the complete, operable assembly. Tested according to ASTM E90.*

Thermiser Max (ESD30) Insulated Rolling Door has a Sound Transmission Class rating of up to 30 for the curtain and up to 22 for the complete, operable assembly. Tested according to ASTM E90.*

TranZform Sound (ESP20) has a Sound Transmission Class rating of 45, when tested according to ASTM E90 standards. 

TranZform Space (ESP10) has a Sound Transmission Class rating of 30, when tested according to ASTM E90 standards.

* If an STC of 32 is desired, additional options are required. Please consult the factory for details. 

Back to Top

 

OSHPD Preapproval of Manufacturer's Certification (OPM)

The SmokeShield Elevator curtain complies with OSHPD. Listing # OPM-0523-19.


Back to Top

Forced Entry / Ballistic Resistance (SD-STD-01.01)

The EntryDefender Door meets the DS certification criteria for 5, 15 and 60 minute forced entry and no ballistic resistance. SD-STD-01.01


Back to Top